Install in a truck or cold box
The device sends over NB-IoT. The probe measures the load.
Every install
- Open the lid. Press and hold the button for 1 second. The LEDs start to blink. Bluetooth should be active. See LED and button.
- Scan the QR with the Tempivo app or a partner app.
- Mount the device with the optional screw bracket, or with the 3M adhesive bracket.
- Place the probe in the air or load you care about.
- Wait until status is online. Check temperature.
NB-IoT coverage is strong almost everywhere. Placement of the device is rarely the issue.
Truck
- Mount on the cab wall, an outer wall, or a plastic box.
- Route the probe cable into the cargo space through a door seal. Do not crush the cable.
- Put the probe in the air stream, not on the cooling unit.
Cold box
- Keep the probe inside. Keep it off the evaporator and the door. Leave slack in the cable.
- Confirm the device is on and status is online.